Revision as of 05:23, 12 December 2012
auxiliarySupplySystem
Scheme description / Schemenbeschreibung
Position of auxiliarySupplySystem in the XML-Tree / Position von auxiliarySupplySystem im XML-Baum
- Parent: wagon
- Children: Not yet described. / Noch nicht beschrieben.
Multiplicity / Anzahl
Semantics / Bedeutung
(after version 2.0)
The element <auxiliarySupplySystem> is used to name the supply systems the auxiliaries of the vehicle can be fed with.
Das Element <auxiliarySupplySystem> wird verwendet, um die Stromsysteme zu benennen, mit denen die Hilfsbetriebe des Fahrzeuges versorgt werden können.
Attributes of auxiliarySupplySystem / Attribute von auxiliarySupplySystem
- voltage: The nominal voltage in Volt for the supply system.
- frequency: The nominal frequency in Hertz for the supply system. '0' means DC system.
Syntactic Constraints / Syntaktische Beschränkungen
- voltage xs:decimal, 1 fraction digit, voltage value measured in Volt, optional
- frequency xs:decimal, 3 fraction digits with minimum value 0, frequency value measured in Hertz, optional
The element is optional and can occur several times.
Best practice & Examples / Empfohlene Anwendung & Beispiele
Not yet described. / Noch nicht beschrieben.
Notes / Anmerkungen
For European railways there are four typical systems:
- 1000 V 16.7 Hz
- 1000 V 50 Hz
- 1500 V DC
- 3000 V DC
Open issues / Offene Punkte/Pendenzen
Not yet described. / Noch nicht beschrieben.