|semantics =
|semantics =
The element {{RS:Tag|dedicatedSupplySystem}} in context of {{RS:Doc|auxiliarySupply}} is used for the capabilities per possible auxiliary supply system.
The element <[[RS:dedicatedSupplySystem_aux|dedicatedSupplySystem]]> in context of {{RS:Doc|auxiliarySupply}} is used for the capabilities per possible auxiliary supply system.


{{deu|Das Element {{RS:Tag|dedicatedSupplySystem}} wird im Kontext von {{RS:Doc|auxiliarySupply}} zur Beschreibung der Leistungsmerkmale für jedes mögliche Hilfsbetriebespeisesystem verwendet.}}
{{deu|Das Element <[[RS:dedicatedSupplySystem_aux|dedicatedSupplySystem]]> wird im Kontext von {{RS:Doc|auxiliarySupply}} zur Beschreibung der Leistungsmerkmale für jedes mögliche Hilfsbetriebespeisesystem verwendet.}}


|parent =
|parent =

Revision as of 11:55, 29 December 2009


dedicatedSupplySystem
 


Scheme description / Schemenbeschreibung

Position of dedicatedSupplySystem in the XML-Tree / Position von dedicatedSupplySystem im XML-Baum

  • Parent: auxiliarySupply
  • Children: Not yet described. / Noch nicht beschrieben.

Multiplicity / Anzahl

[1..1]

Semantics / Bedeutung

The element <dedicatedSupplySystem> in context of auxiliarySupply is used for the capabilities per possible auxiliary supply system.

Das Element <dedicatedSupplySystem> wird im Kontext von auxiliarySupply zur Beschreibung der Leistungsmerkmale für jedes mögliche Hilfsbetriebespeisesystem verwendet.

Attributes of dedicatedSupplySystem / Attribute von dedicatedSupplySystem

  • voltage: The nominal voltage in Volt for the supply system.
  • frequency: The nominal frequency in Hertz for the supply system. '0' means DC system.
  • maxPower: The maximum power, which can be drawn with this supply system.

Syntactic Constraints / Syntaktische Beschränkungen

The element is optional and can occur several times. However, if used a value for maxPower is required.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

For European railways there are four typical systems:

  • 1000 V 16.7 Hz
  • 1000 V 50 Hz
  • 1500 V DC
  • 3000 V DC

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.