RS:winding: Difference between revisions
Jump to navigation
Jump to search
[unchecked revision] | [checked revision] |
(Updated using new template (Vorlage:RailMLType)) |
m (Constrains updated) |
||
Line 30: | Line 30: | ||
* {{Attr|assemblyName}} {{RailMLType|tGenericName}}, mandatory | * {{Attr|assemblyName}} {{RailMLType|tGenericName}}, mandatory | ||
* {{Attr|nominalVoltage}} optional | * {{Attr|nominalVoltage}} {{RailMLType|tVoltageVolt}}, optional | ||
* {{Attr|nominalCurrent}} optional | * {{Attr|nominalCurrent}} {{RailMLType|tCurrentAmpere}}, optional | ||
* {{Attr|transformationRatio}} optional | * {{Attr|transformationRatio}} {{XsdType|decimal}}, optional | ||
* {{Attr|primaryResistance}} optional | * {{Attr|primaryResistance}} {{RailMLType|tResistanceOhm}}, optional | ||
* {{Attr|secondaryResistance}} optional | * {{Attr|secondaryResistance}} {{RailMLType|tResistanceOhm}}, optional | ||
* {{Attr|primaryLeakageInductance}} optional | * {{Attr|primaryLeakageInductance}} {{RailMLType|tInductanceHenry}}, optional | ||
* {{Attr|secondaryLeakageInductance}} optional | * {{Attr|secondaryLeakageInductance}} {{RailMLType|tInductanceHenry}}, optional | ||
The element {{RS:Tag|winding}} is optional and can occur several times. | The element {{RS:Tag|winding}} is optional and can occur several times. |
Revision as of 11:01, 12 December 2012
winding
Scheme description / Schemenbeschreibung
Position of winding in the XML-Tree / Position von winding im XML-Baum
- Parent: <transformer>
- Children: Not yet described. / Noch nicht beschrieben.
Multiplicity / Anzahl
Semantics / Bedeutung
The element <winding> contains the nominal values for each transformer winding.
Das Element <winding> enthält die Bemessungsdaten für die einzelnen Wicklungen des Haupttransformators.
Attributes of winding / Attribute von winding
- assemblyName: This is the type of transformer winding as descriptive name.
- nominalVoltage: This is the nominal voltage of transformer winding at primary side in Volts.
- nominalCurrent: This is the nominal current of transformer winding at primary side in Ampere.
- transformationRatio: This is the transformation ratio of the transformer winding according to the relation of primary/secondary voltage.
- primaryResistance: This is the resistance of primary winding of one transformer in Ohms.
- secondaryResistance: This is the resistance of secondary winding of one transformer in Ohms transformed to primary side.
- primaryLeakageInductance: This is the leakage inductance of primary winding of one transformer in Henry.
- secondaryLeakageInductance: This is the leakage inductance of secondary winding of one transformer in Henry transformed to primary side.
Syntactic Constraints / Syntaktische Beschränkungen
- assemblyName xs:string, mandatory
- nominalVoltage xs:decimal, 1 fraction digit, voltage value measured in Volt, optional
- nominalCurrent xs:decimal, 1 fraction digit, current value measured in Ampere, optional
- transformationRatio xs:decimal, optional
- primaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
- secondaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
- primaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional
- secondaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional
The element <winding> is optional and can occur several times.
Best practice & Examples / Empfohlene Anwendung & Beispiele
Not yet described. / Noch nicht beschrieben.
Notes / Anmerkungen
Not yet described. / Noch nicht beschrieben.
Open issues / Offene Punkte/Pendenzen
Not yet described. / Noch nicht beschrieben.