{{#switch: {{{1}}} | {{#switch: {{{1}}} | ||
| tAccelerationMeterPerSquareSec = {{XsdType|decimal}}, 3 fraction digits, acceleration value measured in m/ | | tAccelerationMeterPerSquareSec = {{XsdType|decimal}}, 3 fraction digits, acceleration value measured in {{unit|m/s²}} | ||
| tAngleDegFullCircle = {{XsdType|decimal}}, 6 digits and 3 fraction digit within the range of '''-180''' and '''+180''', angle value measured in degree | | tAngleDegFullCircle = {{XsdType|decimal}}, 6 digits and 3 fraction digit within the range of '''-180''' and '''+180''', angle value measured in {{unit|degree}} | ||
| tAngleDegQuadrant = {{XsdType|decimal}}, 6 digits and 3 fraction digit with minimum value greater '''0''' and maximum less or equal '''90''', angle value measured in degree | | tAngleDegQuadrant = {{XsdType|decimal}}, 6 digits and 3 fraction digit with minimum value greater '''0''' and maximum less or equal '''90''', angle value measured in {{unit|degree}} | ||
| tAreaSquareMeter = {{XsdType|decimal}}, 3 fraction digits, square area value measured in | | tAreaSquareMeter = {{XsdType|decimal}}, 3 fraction digits, square area value measured in {{unit|m²}} | ||
| tBrakePercentage = {{XsdType|integer}}, within the range of '''6''' and '''225''', brake percentage as value of braking performance in relation to vehicle weight | | tBrakePercentage = {{XsdType|integer}}, within the range of '''6''' and '''225''', brake {{unit|percentage}} as value of braking performance in relation to vehicle weight | ||
| tCounter = {{XsdType|nonNegativeInteger}} | | tCounter = {{XsdType|nonNegativeInteger}} | ||
| tCurrentAmpere = {{XsdType|decimal}}, 1 fraction digit, current value measured in Ampere | | tCurrentAmpere = {{XsdType|decimal}}, 1 fraction digit, current value measured in {{unit|Ampere}} | ||
| tEffortNewton = {{XsdType|decimal}}, 0 fraction digits, effort value measured in Newton | | tEffortNewton = {{XsdType|decimal}}, 0 fraction digits, effort value measured in {{unit|Newton}} | ||
| tElementDescription = {{XsdType|string}} | | tElementDescription = {{XsdType|string}} | ||
| tEnergyKiloWattHours = {{XsdType|decimal}}, 3 fraction digits, energy value measured in kWh | | tEnergyKiloWattHours = {{XsdType|decimal}}, 3 fraction digits, energy value measured in {{unit|kWh}} | ||
| tFluxVoltSecond = {{XsdType|decimal}}, 6 fraction digit, electrical flux value measured in Volt | | tFluxVoltSecond = {{XsdType|decimal}}, 6 fraction digit, electrical flux value measured in {{unit|Volt second}}s | ||
| tForceNewton = {{XsdType|decimal}}, 0 fraction digits, force value measured in Newton | | tForceNewton = {{XsdType|decimal}}, 0 fraction digits, force value measured in {{unit|Newton}} | ||
| tForceCoefficentNewton = {{XsdType|decimal}}, 6 fraction digits, force value measured in Newton | | tForceCoefficentNewton = {{XsdType|decimal}}, 6 fraction digits, force value measured in {{unit|Newton}} | ||
| tFrequencyHertz = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''', frequency value measured in Hertz | | tFrequencyHertz = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''', frequency value measured in {{unit|Hertz}} | ||
| tGenericID = {{XsdType|ID}} | | tGenericID = {{XsdType|ID}} | ||
| tGenericName = {{XsdType|string}} | | tGenericName = {{XsdType|string}} | ||
| tGenericRef = {{XsdType|IDREF}} | | tGenericRef = {{XsdType|IDREF}} | ||
| tGradientPromille = {{XsdType|decimal}}, 3 fraction digits, gradient (slope) value measured in per mille | | tGradientPromille = {{XsdType|decimal}}, 3 fraction digits, gradient (slope) value measured in {{unit|per mille}} | ||
| tInductanceHenry = {{XsdType|decimal}}, 6 fraction digit, electrical inductance value measured in Henry | | tInductanceHenry = {{XsdType|decimal}}, 6 fraction digit, electrical inductance value measured in {{unit|Henry}} | ||
| tLength = {{XsdType|decimal}}, 6 fraction digits, applies as basic type for inheritance, should not be used directly because of missing unit of measure | | tLength = {{XsdType|decimal}}, 6 fraction digits, applies as basic type for inheritance, should not be used directly because of missing unit of measure | ||
| tLengthMM = {{XsdType|decimal}}, 6 fraction digits, length value measured in millimeter | | tLengthMM = {{XsdType|decimal}}, 6 fraction digits, length value measured in {{unit|millimeter}} | ||
| tLengthM = {{XsdType|decimal}}, 6 fraction digits, length value measured in meter | | tLengthM = {{XsdType|decimal}}, 6 fraction digits, length value measured in {{unit|meter}} | ||
| tLengthKM = {{XsdType|decimal}}, 6 fraction digits, length value measured in kilometer | | tLengthKM = {{XsdType|decimal}}, 6 fraction digits, length value measured in {{unit|kilometer}} | ||
| tOneToZero = {{XsdType|decimal}}, range between '''0''' and '''1''' (inclusive borders), maximum 6 fraction digits | | tOneToZero = {{XsdType|decimal}}, range between '''0''' and '''1''' (inclusive borders), maximum 6 fraction digits | ||
| tPassengersPerSecond = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''' | | tPassengersPerSecond = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''' | ||
| tPositiveCounter = {{XsdType|positiveInteger}} | | tPositiveCounter = {{XsdType|positiveInteger}} | ||
| tPowerWatt = {{XsdType|decimal}}, 0 fraction digits, power value measured in Watt | | tPowerWatt = {{XsdType|decimal}}, 0 fraction digits, power value measured in {{unit|Watt}} | ||
| tRadiusM = {{XsdType|decimal}}, 6 fraction digits, radius value measured in meter | | tRadiusM = {{XsdType|decimal}}, 6 fraction digits, radius value measured in {{unit|meter}} | ||
| tResistanceOhm = {{XsdType|decimal}}, 3 fraction digit, electrical resistance value measured in | | tResistanceOhm = {{XsdType|decimal}}, 3 fraction digit, electrical resistance value measured in {{unit|Ohm}}s | ||
| tRotationalFrequencyRevolutionsPerMinute = {{XsdType|positiveInteger}}, rotational frequency value measured in number of revolutions per minute | | tRotationalFrequencyRevolutionsPerMinute = {{XsdType|positiveInteger}}, rotational frequency value measured in number of {{unit|revolutions per minute}} | ||
| tSpeedDegreesPerSecond = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''', angle rotation speed value measured in degrees per second | | tSpeedDegreesPerSecond = {{XsdType|decimal}}, 3 fraction digits with minimum value '''0''', angle rotation speed value measured in {{unit|degrees per second}} | ||
| tSpeedKmPerHour = {{XsdType|decimal}}, 5 digits and 1 fraction digit with minimum value '''0''', speed value measured in km/h | | tSpeedMPerSec={{XsdType|decimal}}, 5 digits and 1 fraction digit with minimum value '''0''', generic type for speed/velocity values measured in {{unit|meter per second}} | ||
| tVoltageVolt = {{XsdType|decimal}}, 1 fraction digit, voltage value measured in Volt | | tSpeedKmPerHour = {{XsdType|decimal}}, 5 digits and 1 fraction digit with minimum value '''0''', speed value measured in {{unit|km/h}} | ||
| tWeightTons = {{XsdType|decimal}}, 3 fraction digits, weight value measured in metric | | tVoltageVolt = {{XsdType|decimal}}, 1 fraction digit, voltage value measured in {{unit|Volt}} | ||
| tWeightKG=generic {{XsdType|decimal}}, 3 fraction digits, type for weight/load values measured in {{unit|kilogram}} | |||
| tWeightTons = {{XsdType|decimal}}, 3 fraction digits, weight value measured in {{unit|metric ton}}s | |||
| tVersionNumber = {{XsdType|string}} | | tVersionNumber = {{XsdType|string}} | ||
| tVolumeCubicMeter = {{XsdType|decimal}}, 3 fraction digits, cubical volume value measured in | | tVolumeCubicMeter = {{XsdType|decimal}}, 3 fraction digits, cubical volume value measured in {{unit|m³}} | ||
| tVolumeLitre = {{XsdType|decimal}}, 3 fraction digits, cubical volume value measured in litre | | tVolumeLitre = {{XsdType|decimal}}, 3 fraction digits, cubical volume value measured in {{unit|litre}} | ||
| tLaxDirection = {{xsdType|string}}, generic type for direction statements: enumeration up, down, unknown, none, both | | tLaxDirection = {{xsdType|string}}, generic type for direction statements: enumeration up, down, unknown, none, both | ||
| tDelimitedDirection ={{xsdType|string}}, generic type for more constrained direction statements: enumeration up, down, unknown; derived from tLaxDirection | | tDelimitedDirection ={{xsdType|string}}, generic type for more constrained direction statements: enumeration up, down, unknown; derived from tLaxDirection | ||
| tMileageDirection = {{xsdType|string}}, generic type for mileage direction statements; enumeration rising, falling | | tMileageDirection = {{xsdType|string}}, generic type for mileage direction statements; enumeration rising, falling | ||
| tMeterloadTonsPerMeter={{xsdType|decimal}}, generic type for load per meter values measured in ton per meter; fractionDigits 3; derived from tMeterLoad | | tMeterloadTonsPerMeter={{xsdType|decimal}}, generic type for load per meter values measured in {{unit|ton per meter}}; fractionDigits 3; derived from tMeterLoad | ||
| tTrainProtectionMedium={{xsdType|string}} | | tTrainProtectionMedium={{xsdType|string}} | ||
| tTrainProtectionMonitoring={{xsdType|string}} | | tTrainProtectionMonitoring={{xsdType|string}} |